Fire risk in silos: what can be anticipated with temperature and CO₂
Which signals from a silo can be followed continuously, what a timely alert anticipates about grain heating and self-combustion, and what falls outside a monitoring system.
In many plants, a silo is checked through inspection rounds and periodic controls. Between one check and the next, what happens inside is not seen. The Growcast manual names that blind spot as a permanent operational risk: fires, pests or equipment breakdowns that could have been anticipated with a timely alert.
This note is about which part of that risk can be followed with sensors and which part cannot. A monitoring system does not detect or put out a fire. It makes it possible to see earlier the conditions worth attending to.
Why a silo heats up
Stored grain keeps respiring and produces heat. According to INTA, the activity of fungi and microorganisms consumes oxygen and releases CO₂ and heat, and once started, these processes feed back and accelerate.
That heating is one of the conditions associated with self-combustion. Not every fire in a plant starts this way: causes outside the grain mass, such as an electrical or equipment failure, are not anticipated by measuring the inside of the silo.
What can be followed continuously
| Variable | What it provides |
|---|---|
| Interior temperature | The thermal evolution of each silo, with its history. |
| Interior relative humidity | A reference for the risk of biological activity. |
| CO₂ | An indicator of biological activity: grain, fungi and insects respiring. |
| Exterior temperature and humidity | The information to decide when aeration is worthwhile. |
| Aerator status and hours | The record of when and how much aeration was used. |
INTA uses the relative humidity of the air between the grains as a reference: below 67 % storage is safe, between 67 % and 85 % respiration grows, and above 85 % respiration is intense, with fungi and heating. For CO₂, the reference values depend on the size of the silo and the storage time, so they are defined for each installation.
How the warning is set up
- 01A range on the screen
The expected range of each variable is defined. A deviation shows on the panel and is recorded.
- 02A threshold on the phone
A threshold is defined for the critical condition. That is the warning that reaches the phone.
- 03Acknowledgement
Whoever reads the alarm acknowledges it, leaving a record that someone saw it.
What a monitoring system does not do
- It does not detect flames or smoke, and it does not put out a fire.
- It does not replace the safety measures of the plant or its emergency plan.
- A reading corresponds to the point where the sensor is, not to the whole silo.
- An alert is useful if someone attends to it: it is worth defining who receives it and what they do.
Closing
- Stored grain produces heat, and that process can accelerate.
- Temperature, humidity and CO₂ make it possible to follow it continuously, not only on each round.
- CO₂ reference values are defined for each installation.
- Monitoring anticipates conditions; the safety of the plant remains a separate layer.
A timely alert does not put out a fire: it gives room to attend to the condition that can lead to one.
References for this note: Bartosik and de la Torre, CO2NTROL, INTA EEA Balcarce, December 2023.
Drawn from the Growcast platform user manual. Values in the figures are illustrative.